Current research projects

Image Investigation of material-dependent parameters
Image Thermal engines
Image Cryostats, Non-Metallic and Metallic
Image Humidifier System for High-Purity Gases
Image Low Temperature Measuring Service
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Certifiable connection types in cryogenics
Image Testzentrum PLWP at ILK Dresden
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Panel with indirect evaporative cooling via membrane
Image All-in-one device for freeze-drying and production of biomaterial
Image Swirl-free on the move...
Image Pulse-Tube-Refrigerator with sealed compressor
Image Non- invasive flow measurements

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Software for test rigs

Individual software for complex tests and evaluation

Image

Brine (water)-water heat pump

Test according DIN EN 14511 and 14825

Image

High temperature heat pump

Using waste heat from industrial processes

Image

Air-water heat pumps

Test according DIN EN 14511 and 14825

Image

Micro heat exchangers in refrigeration

3D-printing of micro heat exchangers