Current research projects

Image Investigation according to DIN EN ISO 14903
Image Helium extraction from natural gas
Image Performance tests of condensing units
Image Cryostats, Non-Metallic and Metallic
Image Hydrogen and methane testing field at the ILK
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Software for technical building equipment
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Behavior of multiphase cryogenic fluids
Image 3D - Air flow sensor
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Ice Slurry Generation
Image Air-water heat pumps
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Verification of storage suitability of cryo tubes
Image Development of a Cryogenic Magnetic Air Separation Unit

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Heat2Power

Refining of fuel cell waste heat

Image

Reducing the filling quantity

How much refrigerant must be filled?

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?