Current research projects

Image Multifunctional electronic modules for cryogenic applications
Image Low Temperature Measuring Service
Image Filter Tests
Image Test method for high - temperature heat pump - oils
Image Pulse-Tube-Refrigerator with sealed compressor
Image Practical training, diploma, master, bachelor
Image Reduction of primary noise sources of fans
Image Testing of mobile leak detectors according to DIN EN 14624
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Service offer for Leak Detection and Tightness Test
Image Measurements on ceiling mounted cooling systems
Image Hydrogen and methane testing field at the ILK
Image Investigation according to DIN EN ISO 14903
Image All-in-one device for freeze-drying and production of biomaterial
Image Test rigs for refrigeration and heat pump technology
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings

You are here:   /  Home


Corrosion inhibitor for ammonia absorption systems

EURONORM GmbH

07/2021-08/2023

Dr. rer. nat. Franziska Krahl

+49-351-4081-5421

An alternative to chromium(VI) compounds

Project management: Dr. Franziska Krahl, Dr. Steffen Feja

Unlike electrically driven compression chillers or compression heat pumps, ammonia absorption systems (chillers and heat pumps) are driven by thermal energy. If the thermal energy comes from solar thermal energy, geothermal energy or waste heat, for example, these machines can be operated without fossil fuels. The working substances water and ammonia used are naturally occurring compounds, do not contribute to global warming (GWP = 0) and also have no ozone depletion potential (ODP).

The research project focused on identifying a suitable corrosion inhibitor for ammonia absorption systems to replace chromium(VI) compounds. A strategy was developed to enable the investigation of a large number of potential alternatives. From a total of more than 200 substance combinations (test approaches), 12 promising alternatives for further laboratory tests were identified using a rapid test developed in the project.

The rapid test developed proved to be very efficient in terms of identifying potential corrosion inhibitors. By using sealed reaction chambers, this test can also be carried out at significantly higher temperatures, which means that conditions close to the application are already present during screening.

At the end of the research project, 3 chromium(VI)-free corrosion inhibitors for ammonia absorption systems will be available, the basic suitability of which has been proven in laboratory tests. Their effectiveness is now to be tested in demonstrators.


Your Request

Further Projects

Image

Measurements on ceiling mounted cooling systems

Comparative performance measurement

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications