Aktuelle Forschungsprojekte

Image Corrosion inhibitor for ammonia absorption systems
Image Micro heat exchangers in refrigeration
Image Multifunctional electronic modules for cryogenic applications
Image Filter Tests
Image Combined building and system simulation
Image Performance tests of refrigerant compressors
Image Thermostatic Expansion Valves
Image Preformance measurements of heat exchangers
Image Computational fluid dynamics CFD
Image IN-SITU SWELLING BEHAVIOUR OF POLYMER MATERIALS IN FLAMMABLE FLUIDS
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Testing of mobile leak detectors according to DIN EN 14624
Image Certifiable connection types in cryogenics
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Test procedures for electrical components

You are here:   /  Home


Low Temperature Tribology

Industry and R&D

Dipl.-Ing. Gunar Schroeder

+49-351-4081-5129

Tribological studies at cryogenic temperatures

For special applications at cryogenic temperatures the use of dry friction is necessary because the working temperatures are significant lower than the working range of liquid lubricants.

The ILK Dresden has extensive experience in the field of material testing at cryogenic temperatures and has developed a measuring system (from roomtemperature down to cryogenic temperatures) to determine the roughness and the coefficient of friction of different sliding material combinations.

The test stand consists of an experimental platform and a traversing mechanism with a force sensor, which is controlled via PC. The direct measurement of the friction force is carried out by the distance covered. Measurements can be performed down to −196 °C (lower temperatures on request). The cooling of the experimental platform and the samples is realised by a controlled liquid nitrogen heat exchanger/evaporator. Measurements are performed under an atmosphere of gaseous nitrogen to prevent the ingress of moisture. Thereby the experimental samples have no direct contact to liquid nitrogen. The uniform temperature distribution is measured by thermocouples, which are calibrated at the ILK Dresden.

Advantages: modular test setup which can be changed to specific requirements; adjustment of sample geometry and/or test track is possible.

Parameter

Measuring accuracyMeasuring range 0.4 N to 2 N≤ 1 % of measured value
Measuring range 2 N to 100 N≤ 0.5 % of measured value
Measuring range extendible up to 5 kN

Repeatability
(e.g. PTFE)

± 0.05 N respectively 1.5 % of coefficient of friction

Your Request