Current research projects

Image Hydrogen and methane testing field at the ILK
Image Thermostatic Expansion Valves
Image Brine (water)-water heat pump
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Multifunctional electronic modules for cryogenic applications
Image Air-flow test rig for fan characteristic measurement
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image High temperature heat pump
Image Performance tests of refrigerant compressors
Image Solar Cooling
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Micro heat exchangers in refrigeration
Image Filter Tests
Image Lifetime prediction of hermetic compressor systems
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings

You are here:  Home /  Measurements and Tests


Electrochemical decontamination of electrically conducting surfaces „EDeKo II“

Dr. rer. nat. Torsten Burkholz

+49-351-4081-5410

Improvement of sanitary prevention by electrochemical decontamination

Due to the risk of widely spreading illnesses and pandemic diseases, hygiene is becoming more and more important on a global scale. One method to reduce breakouts is prevention by eliminating dangerous contamination of surfaces (decontamination). Under the direction of Dr. Burkholz, the ILK Dresden is doing research on an economic and effective method, the method of electrochemial deconamination of electrically conducting surfaces, to improve and extend existing sanitary measures. The effect of the decontamination method is an electrochemical attack proceeding from the contaminated surface. This could be the surface of medical equipment, for example. By the electrochemical generation of reactive oxygen species (ROS), all attached biological material is destroyed. Even biofilm, which protects itself from chemical detergents by a mucous layer, can be destroyed effectively with the help of this principle.

Field of use

Improvement of existing cleaning, sterilization and decontamination processes, e.g. in medicine, air-conditioning and ventilation engineering, the food industry and cleanroom technology.

Objective

„EDeKo II“ will deal with the generation of reactive oxygen species as well as material stability under increased temperatures, the impact of flow effects and different pressures. Furthermore, new devices will be developed and built, which ensure electrochemical decontamination under application-relevant circumstances.

Procedure

In the previous project „EDeKo“, the generation of reactive oxygen species (ROS) has been optimized on a laboratory scale under set conditions. In „EDeKO II“, the impact of diverse factors on the generation of ROS will be checked, such as a variable electrode gap, an altered relation between anode and cathode area as well as different pressures and temperatures. For the experimental measurement, new electrochemical cells will be designed and built, which create the distance of the electrodes to one another in defined steps variably and ensure different geometries for the anode.

Picture material

The experimental basis for the electrochemical analysis will be the Potentiostat Metrohm Autolab PGSTAT 204, in which temperatures of up to 95°C and pressure of up to 10 bar maximum are possible, including the related measurement and evaluation software (Nova 2.0) as well as different stainless steel pressure containers, e.g. see-through sterilizers, which have been developed at the ILK Dresden.

Abbildung: Cyclovoltammogramme einer Cu-Arbeitselektrode gegen die Ag/AgCl-Elektrode mit der in Kaliumphosphat-Puffer (pH 7; blau), Kaliumdihydrogenphosphat-Lösung (pH 4,5; dunkelgrün), Dikaliumhydrogenphosphat-Lösung (pH 9,2; rot), Natriumsulfat-Lösung (pH 5,9; orange), Natriumcitrat-Lösung (pH 8,3; hellgrün) und Natrium-Bicarbonatpuffer (pH 6,5; violett).

Abbildung: Bild1 Elementverteilung einer mit Protein behandelten Cu-Oberfläche ohne elektrochemische Vorbehandlung. Bild2 Nach elektrochemischer Vorbehandlung.

Related links

https://www.wotech-technical-media.de/womag/ausgabe/2014/05/24_med_burkholz_05j2014/24_med_burkholz_05j2014.php (Link to WoMag-Publikation)

https://publikationen.sulb.uni-saarland.de/handle/20.500.11880/22719 (Dissertation)

T. Burkholz, Elektrochemische Dekontamination elektrisch leitfähiger Oberflächen (EDeKo) - Abschlussbericht, EURONORM GmbH, VF160045 (2019).

C. Jacob, G. Kirsch, A. Slusarenko, P.G. Winyard, T. Burkholz (eds.), Recent Advances in Redox Active Plant and Microbial Products: From basic chemistry to widespread applications in Medicine and Agriculture, Springer Science, ISBN: 978-9401789523 (2015).

T. Burkholz, C. Jacob, A word on redox activity, in: C. Jacob, G. Kirsch, A. Slusarenko, P.G. Winyard, T. Burkholz (eds.), Recent Advances in Redox Active Plant and Microbial Products: From basic chemistry to widespread applications in Medicine and Agriculture, Springer Science (2015).

U.M. Viswanathan, T. Burkholz, C. Jacob, Electrochemistry at the edge of reason: Chalcogen-based redox systems in biochemistry and drug design, Zeitschrift für Physikalische Chemie, 227(5), 691-706 (2013).

E. Domínguez Álvarez, U.M. Viswanathan, T. Burkholz, K. Khairan, C. Jacob, Bio-Electrochemistry and Chalcogens, Chapter 7, in M. Schlesinger (ed.), Applications of Electrochemistry in Medicine, Modern Aspects of Electrochemistry, 56, 249-282 (2013).


Your Request

Further Projects - Measurements and Tests

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Calibration of Low Temperature Sensors

According to the comparative measurement method

Image

Low Temperature Measuring Service

Measurement of Thermal Properties at Low Temperatures

Image

Test procedures for electrical components

Insulating properties of hermetic compressors