Current research projects

Image Development of a Cryogenic Magnetic Air Separation Unit
Image Test procedures for electrical components
Image Low Temperature Tribology
Image Innovative Parahydrogen Generator Based on Magnets
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image IO-Scan - Integral measuring optical scanning method
Image Energy efficiency consulting - cogeneration systems
Image Corrosion inhibitor for ammonia absorption systems
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Laseroptical measurement
Image Calibration leak for the water bath leak test
Image Panel with indirect evaporative cooling via membrane
Image Software modules
Image Verification of storage suitability of cryo tubes
Image Calibration of Low Temperature Sensors
Image High Capacity Pulse Tube Cooler

You are here:  Home /  Measurements and Tests


Corrosion inhibitor for ammonia absorption systems

EURONORM GmbH

07/2021-08/2023

Dr. rer. nat. Franziska Krahl

+49-351-4081-5421

An alternative to chromium(VI) compounds

Project management: Dr. Franziska Krahl, Dr. Steffen Feja

Unlike electrically driven compression chillers or compression heat pumps, ammonia absorption systems (chillers and heat pumps) are driven by thermal energy. If the thermal energy comes from solar thermal energy, geothermal energy or waste heat, for example, these machines can be operated without fossil fuels. The working substances water and ammonia used are naturally occurring compounds, do not contribute to global warming (GWP = 0) and also have no ozone depletion potential (ODP).

The research project focused on identifying a suitable corrosion inhibitor for ammonia absorption systems to replace chromium(VI) compounds. A strategy was developed to enable the investigation of a large number of potential alternatives. From a total of more than 200 substance combinations (test approaches), 12 promising alternatives for further laboratory tests were identified using a rapid test developed in the project.

The rapid test developed proved to be very efficient in terms of identifying potential corrosion inhibitors. By using sealed reaction chambers, this test can also be carried out at significantly higher temperatures, which means that conditions close to the application are already present during screening.

At the end of the research project, 3 chromium(VI)-free corrosion inhibitors for ammonia absorption systems will be available, the basic suitability of which has been proven in laboratory tests. Their effectiveness is now to be tested in demonstrators.


Your Request

Further Projects - Measurements and Tests

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?

Image

Measurement of insulated packaging

How efficient is my cool box?

Image

Cold meter

The fast way to refrigerating capacity

Image

Verification of storage suitability of cryo tubes

Artificial aging of primary packaging for biobanking applications