Current research projects

Image Non- invasive flow measurements
Image Test procedures for electrical components
Image IO-Scan - Integral measuring optical scanning method
Image Swirl-free on the move...
Image High Capacity Pulse Tube Cooler
Image Reduction of primary noise sources of fans
Image Energy efficiency consulting - cogeneration systems
Image Innovative small helium liquefier
Image Refrigerants, lubricants and mixtures
Image Modular storage system for solar cooling
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Test method for high - temperature heat pump - oils
Image Lifetime prediction of hermetic compressor systems
Image Performance tests of condensing units
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr

You are here:  Home /  Measurements and Tests


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects - Measurements and Tests

Image

Verification of storage suitability of cryo tubes

Artificial aging of primary packaging for biobanking applications

Image

Preformance measurements of heat exchangers

Is the heat exchanger properly sized?

Image

Filter Tests

INDUSTRIAL AND LABORATORY PRECIPITATORS

Image

Investigation of coolants

Secondary loop refrigerants