Tribologische Untersuchungen im System Öl-Kältemittel-Werkstoff

Dr.-Ing. Margrit Junk

+49-351-4081-754

Modifizierte Almen-Wieland-Maschine

The modified Almen-Wieland wear testing machine is used for the determination of the tribological properties of oil-refrigerant-bearing-systems under mixed friction conditions. The interaction of lubricants, additives, refrigerants and materials is tested. On the basis of these investigations refrigeration oils and materials could be preselected, but the tests can not substitute field test with refrigeration machines.

Principle

Two half bearings are pressed hydraulically against a test pin rotating horizontally in the lubricant.

The extreme pressure failure, i. e. the load bearing capacity of oil, is determined by increasing continuously or stepwise the test load until seizure of pin and bearing occurs and the pin breaks. The coefficient of friction and the wear are determined with constant (low) load applied during a prescribed test time.

Specialties

  • Hermetic test cell, which allows testing with refrigerant pressures up to 10 bar.
  • Thermostated test cell for a defined lubricant temperature.
  • Continuous record of fest force, turning moment, pressure of refrigerant, temperature and wear.
  • Use of both Almen-Wieland and half bearings with Falex geometry (dimensions of the V-block than the original Falex bearings according to ASTM D 3233).
  • Adaption of the tribological system by choosing materials of test pins and half bearings.

Our services

  • Evaluation of lubricant-refrigerant-material-systems by load bearing capacity of lubricant (extreme pressure failure load), coefficient of friction, wear, changes of lubricant
  • Evaluation of tribological systems after changing lubricants, refrigerants or bearing materials in order to minimize expensive field tests
  • Failure analysis

 

Contact: werkstoffe@ilkdresden.de


Your Request

Further Projects - Measurements and Tests

Image

Electrochemical decontamination of electrically conducting surfaces „EDeKo II“

Improvement of sanitary prevention by electrochemical decontamination

Image

Electrical components in refrigeration circuits

High voltage tests under real conditions

Image

Investigation of materials

Investigations regarding the compatibility of materials with refrigerants, oils and heat transfer fluids


Contact

Institut für Luft- und Kältetechnik - Gemeinnützige Gesellschaft mbH
Bertolt-Brecht-Allee 20, 01309 Dresden


Secretary to the Management

+49-351-4081-520

+49-351-4081-525

Image ISO 9001
Bild Zuse Mitglied Bild SIG