Aktuelle Forschungsprojekte

Image Humidifier System for High-Purity Gases
Image Innovative small helium liquefier
Image Multifunctional electronic modules for cryogenic applications
Image Investigation of coolants
Image High temperature heat pump
Image Range of services laboratory analyses
Image Calibration leak for the water bath leak test
Image Intelligent innovative power supply for superconducting coils
Image Thermal engines
Image Electrical components in refrigeration circuits
Image Service offer for Leak Detection and Tightness Test
Image Air-flow test rig for fan characteristic measurement
Image Thermostatic Expansion Valves
Image Performance tests of refrigerant compressors
Image Investigation of materials
Image Panel with indirect evaporative cooling via membrane

You are here:  Home /  Testing Equipment


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects - Testing Equipment

Image

Pulse-Tube-Refrigerator with sealed compressor

for mobil use in the hydrogen technology

Image

3D - Air flow sensor

Anemometer for determination of 3d-air flow