Current research projects

Image Cold meter
Image Micro heat exchangers in refrigeration
Image Panel with indirect evaporative cooling via membrane
Image Refrigerants, lubricants and mixtures
Image Practical training, diploma, master, bachelor
Image Innovative small helium liquefier
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Modular storage system for solar cooling
Image Brine (water)-water heat pump
Image Filter Tests
Image Measurements on ceiling mounted cooling systems
Image Test rigs for refrigeration and heat pump technology
Image 3D - Air flow sensor
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image State of system and failure analyses
Image All-in-one device for freeze-drying and production of biomaterial

You are here:  Home /  Testing Equipment


3D - Air flow sensor

Industry

on request

Dr. Ralph Krause

+49-351-4081-5318

Anemometer for determination of 3d-air flow

Measuring System for determination of three-dimensional air flow conditions

The termal air flow sensor on flow-through-basis is an air velocity anemometer for determination oft he amount and the direction of a three-dimensional air flow in a gaseous fluid. The main application field is the determination of very low air velocities with changeable flow direction and high turbulence rates.

Application

The new thermal flow sensor on flow-through-basis enables the determination of the air flow vector in a three-dimensional air flow field on a most simple way and with very high accuracy.

If there are turbulent air flows the effect of turbulence on the measuring result is considered. The actual flow vector is recorded in a large time resolution. Therefore the determination of an unsteady flow vector is possible too.

No special knowledge for the realization of the measuring tasks is required from the user. The measuring system is simple to handle and mechanically very robust.

The determination of flow vector is carried out online. By this way the demand for one measurement is limited on minimum. 

Advantages for the user

  • Large measuring range: 0.01 .. 10 m/s
  • Measurement of very low flow velocities is possible
  • Measurement of unsteady air flows
  • Determination and Consideration of turbulence rate
  • Real time measurement with 0.1 s time resolution for air flow velocity and direction
  • No sensor adjustment for the determination of flow direction is needed
  • No special knowledge for the realization of measuring tasks is needed
  • Calibration for several velocity ranges
  • A lot of possibilities for supervision and control functions

Technische Daten

FluidAir
Flow velocity
(measuring ranges)
0..0,5 0..1, 0..2, 0..5, 0..10 m/s
Flow direction3D room
Measuring accuracy1..5 %, depending on the measuring range
Turbulence ratedetermination from 0 %
Turbulence rate correctionconsideraton of turbulence effect
GrenzfreqFrequency limituenz140 Hz
Update interval10 ms
Data outputanalog/ digital
Interface

Ethernet

Zubehör

Software with individual adaption to specific requirementsdetermination of thermal behavior

recording of three-dimensional flow fields

supervision, controlling
Further mesuring pointse.g. temperature, humidity, radiation, air pressure
Sensor positioninglaser pointer
Options    Transport box, tripod, laptop, printer, data logger, controlling component

Your Request

Further Projects - Testing Equipment

Image

Low temperature – test facilities

thermal cycling tests at very low temperatures

Image

All-in-one device for freeze-drying and production of biomaterial

with automated freezing and sterilisation option

Image

Corrosion inhibitor for ammonia absorption systems

An alternative to chromium(VI) compounds

Image

High temperature heat pump

Using waste heat from industrial processes

Image

Electrochemical decontamination of electrically conducting surfaces „EDeKo II“

Improvement of sanitary prevention by electrochemical decontamination