Aktuelle Forschungsprojekte

Image Testzentrum PLWP at ILK Dresden
Image Measurement of insulated packaging
Image Testing of mobile leak detectors according to DIN EN 14624
Image Software for technical building equipment
Image Preformance measurements of heat exchangers
Image Non- invasive flow measurements
Image Performance tests of refrigerant compressors
Image Cryogenic liquid piston pumps for cold liquefied gases like LIN, LOX, LHe, LH2, LNG, LAr
Image Reduction of primary noise sources of fans
Image Filter Tests
Image Practical training, diploma, master, bachelor
Image Range of services laboratory analyses
Image All-in-one device for freeze-drying and production of biomaterial
Image Helium extraction from natural gas
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Development of test methods and test rigs for stationary integrated refrigeration units

You are here:  Home /  Testing Equipment


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects - Testing Equipment