Aktuelle Forschungsprojekte

Image Corrosion inhibitor for ammonia absorption systems
Image Micro fluidic expansion valve
Image Software modules
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Combined building and system simulation
Image Thermostatic Expansion Valves
Image Energy efficiency consulting - cogeneration systems
Image Test rigs for refrigeration and heat pump technology
Image 3D - Air flow sensor
Image Service offer for Leak Detection and Tightness Test
Image Low Temperature Measuring Service
Image Preformance measurements of heat exchangers
Image Intelligent innovative power supply for superconducting coils
Image Pulse-Tube-Refrigerator with sealed compressor

You are here:   /  Home


Certifiable connection types in cryogenics

BMWI

Dr. Andreas Kade

+49-351-4081-5117

Detachable and permanent connections, adhesive bond / form closure / force closure

The applications of cryogenic and vacuum technology impose special requirements on connection technologies. To determine the appropriate connections the application parameters such as temperature, vacuum and pressure, leak rate, materials, surface properties, radiation resistance, magnetic permeability etc. should be considered.

Connection technologies even if not being part of a standardized process more often have to be subject of a certification or qualification due to increasing quality requirements, e.g. pressure equipment directive 2014/68/EU. Therefore adequate designing and testing is necessary.

Innovations

The intended innovations relate to complete cryogenic systems considering the process chain from room temperature to low temperature range regarding the respectively required specifications. 

  • Development of application-related connection technologies with defined requirements and derived mechanical limit values 
  • Examination of existing connection technologies regarding applicability and further development towards secure and functional technologies
  • Evaluation and definition of application limits to aim for a feasible certification and the subsequent conformity with European guidelines

Project objectives

  • Application-related examination of various connection technologies
  • Further development and adaptation of existing connections to the requirements of cryogenic and vacuum technology
  • Examination on composite materials 
  • Examination on component geometries and their influence on the connection
  • Determination of process parameters (e.g. TIG welding, brazing,...) 
  • Determination of test limit values, especially for test specimens deviating from standards
  • Calculation according to common standards, simulation (FEM, ...) and testing
  • Realization and certification of selected connection technologies

Your Request