Current research projects

Image Measurements on ceiling mounted cooling systems
Image Preformance measurements of heat exchangers
Image Cool Up
Image ZeroHeatPump
Image Intelligent innovative power supply for superconducting coils
Image Low noise and non metallic liquid-helium cryostat
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Investigation of material-dependent parameters
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Refrigerants, lubricants and mixtures
Image Test rigs for refrigeration and heat pump technology
Image High Capacity Pulse Tube Cooler
Image Micro fluidic expansion valve
Image Investigation of coolants
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Characterisation of Superconductors in Hydrogen Atmosphere

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³