Current research projects

Image Calibration leak for the water bath leak test
Image Micro fluidic expansion valve
Image Micro heat exchangers in refrigeration
Image Humidifier System for High-Purity Gases
Image Investigation of coolants
Image Software for technical building equipment
Image Laseroptical measurement
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Air-flow test rig for fan characteristic measurement
Image Low Temperature Measuring Service
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Range of services laboratory analyses
Image Performance tests of refrigerant compressors
Image Intelligent innovative power supply for superconducting coils
Image High temperature heat pump
Image Service offer for Leak Detection and Tightness Test

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects