Current research projects

Image CO₂ GAS HYDRATES FOR SUSTAINABLE ENERGY AND COOLING SOLUTIONS
Image Testzentrum PLWP at ILK Dresden
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Humidifier System for High-Purity Gases
Image Multifunctional electronic modules for cryogenic applications
Image Energy efficiency consulting - cogeneration systems
Image Low Temperature Tribology
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Investigation according to DIN EN ISO 14903
Image 3D - Air flow sensor
Image Tensile and compression testing
Image Behavior of multiphase cryogenic fluids
Image Micro heat exchangers in refrigeration
Image Optimizing HVAC operation with machine learning
Image Service offer for Leak Detection and Tightness Test

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request