Current research projects

Image Innovative small helium liquefier
Image IO-Scan - Integral measuring optical scanning method
Image Thermostatic Expansion Valves
Image Ionocaloric cooling
Image Swirl-free on the move...
Image Thermal engines
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Range of services laboratory analyses
Image Multifunctional electronic modules for cryogenic applications
Image ZeroHeatPump
Image Software for test rigs
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Corrosion inhibitor for ammonia absorption systems
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Performance tests of condensing units
Image Service offer for Leak Detection and Tightness Test

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³