Current research projects

Image Ice Slurry Generation
Image All-in-one device for freeze-drying and production of biomaterial
Image Swirl-free on the move...
Image Optimizing HVAC operation with machine learning
Image Air-water heat pumps
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Solar Cooling
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image IO-Scan - Integral measuring optical scanning method
Image Performance tests of refrigerant compressors
Image Measurement of insulated packaging
Image Investigation of materials
Image Computational fluid dynamics CFD
Image Measurements on ceiling mounted cooling systems
Image Cryostats, Non-Metallic and Metallic

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request