Current research projects

Image Helium extraction from natural gas
Image Filter Tests
Image Modular storage system for solar cooling
Image Preformance measurements of heat exchangers
Image Test method for high - temperature heat pump - oils
Image Air-water heat pumps
Image Hydrogen and methane testing field at the ILK
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Testzentrum PLWP at ILK Dresden
Image Test procedures for electrical components
Image Cold meter
Image Innovative Parahydrogen Generator Based on Magnets
Image Tensile and compression testing
Image Measurements on ceiling mounted cooling systems
Image Optimizing HVAC operation with machine learning

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)

Linking the entire life cycle of a multi-functional air handling unit

Image

Software modules

Software for properties of refrigerants

Image

Verification of storage suitability of cryo tubes

Artificial aging of primary packaging for biobanking applications

Image

Preformance measurements of heat exchangers

Is the heat exchanger properly sized?

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h