Current research projects

Image Testing of mobile leak detectors according to DIN EN 14624
Image Electrical components in refrigeration circuits
Image High temperature heat pump
Image Range of services laboratory analyses
Image Investigation according to DIN EN ISO 14903
Image Test procedures for electrical components
Image Innovative Parahydrogen Generator Based on Magnets
Image 3D - Air flow sensor
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Ice Slurry Generation
Image Modular storage system for solar cooling
Image Thermal engines
Image Panel with indirect evaporative cooling via membrane
Image Tribological investigations of oil-refrigerant-material-systems

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Software modules

Software for properties of refrigerants

Image

Verification of storage suitability of cryo tubes

Artificial aging of primary packaging for biobanking applications

Image

Preformance measurements of heat exchangers

Is the heat exchanger properly sized?

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h

Image

Filter Tests

INDUSTRIAL AND LABORATORY PRECIPITATORS