Current research projects

Image Thermostatic Expansion Valves
Image Thermal engines
Image Filter Tests
Image Intelligent innovative power supply for superconducting coils
Image Helium extraction from natural gas
Image Tribological investigations of oil-refrigerant-material-systems
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Low Temperature Measuring Service
Image Certifiable connection types in cryogenics
Image Influenced melting point of water by magnetic field
Image Low Temperature Tribology
Image Service offer for Leak Detection and Tightness Test
Image Investigation of materials
Image Panel with indirect evaporative cooling via membrane

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Hybrid- Fluid for CO2-Sublimation Cycle

Cryogenic cooling by CO2 sublimation

Image

Energy efficiency consulting - cogeneration systems

How efficient is my refrigeration system?

Image

Cold meter

The fast way to refrigerating capacity

Image

Optimizing HVAC operation with machine learning

Intelligent control of HVAC systems – high comfort with low energy demand

Image

Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)

Linking the entire life cycle of a multi-functional air handling unit