Current research projects

Image Tribological investigations of oil-refrigerant-material-systems
Image Intelligent innovative power supply for superconducting coils
Image Innovative Parahydrogen Generator Based on Magnets
Image Helium extraction from natural gas
Image Calibration of Low Temperature Sensors
Image Performance tests of refrigerant compressors
Image Hydrogen and methane testing field at the ILK
Image Innovative small helium liquefier
Image Calibration leak for the water bath leak test
Image CFE-Test of Cooker Hoods
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Lifetime prediction of hermetic compressor systems
Image Air-water heat pumps
Image 3D - Air flow sensor
Image Range of services laboratory analyses
Image Hybrid- Fluid for CO2-Sublimation Cycle

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Optimizing HVAC operation with machine learning

Intelligent control of HVAC systems – high comfort with low energy demand

Image

Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)

Linking the entire life cycle of a multi-functional air handling unit

Image

Software modules

Software for properties of refrigerants

Image

Verification of storage suitability of cryo tubes

Artificial aging of primary packaging for biobanking applications

Image

Preformance measurements of heat exchangers

Is the heat exchanger properly sized?