Current research projects

Image IO-Scan - Integral measuring optical scanning method
Image Calibration leak for the water bath leak test
Image Measurements on ceiling mounted cooling systems
Image Tribological investigations of oil-refrigerant-material-systems
Image Low noise and non metallic liquid-helium cryostat
Image Cryostats, Non-Metallic and Metallic
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Range of services laboratory analyses
Image Calibration of Low Temperature Sensors
Image Testing of mobile leak detectors according to DIN EN 14624
Image Electrical components in refrigeration circuits
Image Investigation according to DIN EN ISO 14903
Image Non- invasive flow measurements
Image Laseroptical measurement
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Hybrid- Fluid for CO2-Sublimation Cycle

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Verification of storage suitability of cryo tubes

Artificial aging of primary packaging for biobanking applications

Image

Preformance measurements of heat exchangers

Is the heat exchanger properly sized?

Image

Innovative small helium liquefier

Liquefaction rates from 10 to 15 l/h