Current research projects

Image Software for test rigs
Image Heat2Power
Image Software for technical building equipment
Image Investigation of material-dependent parameters
Image Testing of mobile leak detectors according to DIN EN 14624
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Swirl-free on the move...
Image Computational fluid dynamics CFD
Image Range of services laboratory analyses
Image CFE-Test of Cooker Hoods
Image Reduction of primary noise sources of fans
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Reducing the filling quantity
Image High temperature heat pump
Image Low Temperature Measuring Service

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Refrigerants, lubricants and mixtures

Determination of working fluid properties

Image

Reduction of primary noise sources of fans

...using numerical and experimental methods with contra-rotating axial fan

Image

Software for technical building equipment

Design cooling load and energetic annual simulation (VDI 2078, VDI 6007, VDI 6020)

Image

Measurements on ceiling mounted cooling systems

Comparative performance measurement

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units