Current research projects

Image State of system and failure analyses
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Performance tests of condensing units
Image Preformance measurements of heat exchangers
Image Reducing the filling quantity
Image Service offer for Leak Detection and Tightness Test
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Investigation of coolants
Image Intelligent innovative power supply for superconducting coils
Image Tensile and compression testing
Image Production of novel barrier layers on polymer materials to reduce hydrogen permeation
Image Brine (water)-water heat pump
Image Ice Slurry Generation
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Test rigs for refrigeration and heat pump technology
Image Micro fluidic expansion valve

You are here:   /  Home


Low Temperature Tribology

Industry and R&D

Dipl.-Ing. Gunar Schroeder

+49-351-4081-5129

Tribological studies at cryogenic temperatures

For special applications at cryogenic temperatures the use of dry friction is necessary because the working temperatures are significant lower than the working range of liquid lubricants.

The ILK Dresden has extensive experience in the field of material testing at cryogenic temperatures and has developed a measuring system (from roomtemperature down to cryogenic temperatures) to determine the roughness and the coefficient of friction of different sliding material combinations.

The test stand consists of an experimental platform and a traversing mechanism with a force sensor, which is controlled via PC. The direct measurement of the friction force is carried out by the distance covered. Measurements can be performed down to −196 °C (lower temperatures on request). The cooling of the experimental platform and the samples is realised by a controlled liquid nitrogen heat exchanger/evaporator. Measurements are performed under an atmosphere of gaseous nitrogen to prevent the ingress of moisture. Thereby the experimental samples have no direct contact to liquid nitrogen. The uniform temperature distribution is measured by thermocouples, which are calibrated at the ILK Dresden.

Advantages: modular test setup which can be changed to specific requirements; adjustment of sample geometry and/or test track is possible.

Parameter

Measuring accuracyMeasuring range 0.4 N to 2 N≤ 1 % of measured value
Measuring range 2 N to 100 N≤ 0.5 % of measured value
Measuring range extendible up to 5 kN

Repeatability
(e.g. PTFE)

± 0.05 N respectively 1.5 % of coefficient of friction

Your Request

Further Projects

Image

Combined building and system simulation

Scientific analysis of thermodynamic processes in buildings and its systems

Image

Heat2Power

Refining of fuel cell waste heat

Image

Reducing the filling quantity

How much refrigerant must be filled?

Image

Performance tests of condensing units

Does your condensing unit perform well?