Aktuelle Forschungsprojekte

Image Measurement of insulated packaging
Image IN-SITU SWELLING BEHAVIOUR OF POLYMER MATERIALS IN FLAMMABLE FLUIDS
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Innovative Parahydrogen Generator Based on Magnets
Image All-in-one device for freeze-drying and production of biomaterial
Image Heat2Power
Image Intelligent innovative power supply for superconducting coils
Image Performance tests of condensing units
Image Test rigs for refrigeration and heat pump technology
Image Measurements on ceiling mounted cooling systems
Image Corrosion inhibitor for ammonia absorption systems
Image Low Temperature Tribology
Image Tribological investigations of oil-refrigerant-material-systems
Image Lifetime prediction of hermetic compressor systems
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures

You are here:   /  Home


Preformance measurements of heat exchangers

Industry

Dipl.-Ing. Markus Müller

+49-351-4081-5218

Is the heat exchanger properly sized?

We support the industry to improve the efficiency of components for cooling systems and heat pumps.

The ILK Dresden offers the following services:

We determine the preformance and pressure losses of plate heat exchangers (evaporators and condensors) or other heat exchangers for liquids in a defined range.
The measurment is based on the following norms

  • DIN EN 306 Heat exchangers - Methods of measuring the parameters necessary for establishing the performance
  • DIN EN 1117 Heat exchangers - Liquid cooled refrigerant condensors - Test procedures for establishing the performance
  • DIN EN 1118 Heat exchangers - Refrigerant cooled liquid coolers - Test procedure for establishing the performance

The test are preformed at a special developed test rig, which can be seen on the following picture.

Operation range of the test rig

  • Kältemittel: Refrigerants: R134a, R404a, R407C, R410A, R507, (others on request)
  • Coolant: Brine
  • Heat carrier: Water
  • Maximum Performance condensor: 70 kW
  • Maximum Performance evaporator: 60 kW

The measurement systems are calibrated regularly.

Additional services

We can support you at following tasks

  • Technical design of components
  • Optimisation of components
  • Software development for technical design and optimisation

Also we can offer you

  • static and time-varying thermal simulations
  • thermography of components

The ILK Dresden has many expertise and a high flexibility in the field of air and refrigeration technology. You will benefit from the broad spectrum of our research directions and technologies as well as the integration of various fields of expertise.


Your Request