Current research projects

Image Innovative small helium liquefier
Image Mass Spectrometer
Image Range of services laboratory analyses
Image Optimizing HVAC operation with machine learning
Image Investigation according to DIN EN ISO 14903
Image Air-flow test rig for fan characteristic measurement
Image Lifetime prediction of hermetic compressor systems
Image Brine (water)-water heat pump
Image High Capacity Pulse Tube Cooler
Image Intelligent innovative power supply for superconducting coils
Image Energy efficiency consulting - cogeneration systems
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Software for technical building equipment
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image ZeroHeatPump
Image Tribological investigations of oil-refrigerant-material-systems

You are here:   /  Home


Tensile and compression testing

Industry and research institutes

Gunar Schroeder

+49-351-4081-5129

Determination of yield strength, tensile strength and elongation at break

A tensile or compression test is a quasi-static, destructive test method for determining material characteristics such as yield strength, tensile strength and elongation at break. The specimen form and the procedure of such tests are standardized. The ISO 9862 standard defines the exact procedure and the measured variables to be recorded for metallic materials and the DIN 50125 standard defines the specimen shape and its production method. In addition, the arrangement can generally be used to record force-displacement curves with high accuracy.

To carry out the test, the specimens are clamped centrally in the grippers or positioned centrally between the compression plates. In the tensile test, the specimens are pulled apart in a defined manner. In the compression test, on the other hand, a compressive force is applied to the test specimen, e.g. rectangular prisms, cylinders or tubes, in a uniaxial stress state. In both tests, the force and change in length are recorded continuously and evaluated graphically. On request, the tensile and compression test can be carried out at very low temperatures.

Parameter Limit values samples
Materials foils, plastics, composites, metals
Typical dimension of plastic samples Lר: 200×10 mm (7.8"×0.4") or
L×W×H: 200×10×10 mm (7.8"×0.4"×0.4")
Measurement range of force and displacement ±5 kN (±1124 lbf), 400 mm (15.8")
Standardized testing force-distance, force-time, tension-extension

 