Current research projects

Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image ZeroHeatPump
Image Verification of storage suitability of cryo tubes
Image Reducing the filling quantity
Image Behavior of multiphase cryogenic fluids
Image Software for technical building equipment
Image Combined building and system simulation
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Filter Tests
Image Solar Cooling
Image Range of services laboratory analyses
Image Low Temperature Tribology
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Low Temperature Measuring Service
Image High Capacity Pulse Tube Cooler

You are here:   /  Home


Tribological investigations of oil-refrigerant-material-systems

Dr.-Ing. Margrit Junk

+49-351-4081-5419

Modified Almen-Wieland wear testing machine

The modified Almen-Wieland wear testing machine is used for the determination of the tribological properties of oil-refrigerant-bearing-systems under mixed friction conditions. The interaction of lubricants, additives, refrigerants and materials is tested. On the basis of these investigations refrigeration oils and materials could be preselected, but the tests can not substitute field test with refrigeration machines.

Principle

Two half bearings are pressed hydraulically against a test pin rotating horizontally in the lubricant.

The extreme pressure failure, i. e. the load bearing capacity of oil, is determined by increasing continuously or stepwise the test load until seizure of pin and bearing occurs and the pin breaks. The coefficient of friction and the wear are determined with constant (low) load applied during a prescribed test time.

Specialties

  • Hermetic test cell, which allows testing with refrigerant pressures up to 10 bar.
  • Thermostated test cell for a defined lubricant temperature.
  • Continuous record of fest force, turning moment, pressure of refrigerant, temperature and wear.
  • Use of both Almen-Wieland and half bearings with Falex geometry (dimensions of the V-block than the original Falex bearings according to ASTM D 3233).
  • Adaption of the tribological system by choosing materials of test pins and half bearings.

Our services

  • Evaluation of lubricant-refrigerant-material-systems by load bearing capacity of lubricant (extreme pressure failure load), coefficient of friction, wear, changes of lubricant
  • Evaluation of tribological systems after changing lubricants, refrigerants or bearing materials in order to minimize expensive field tests
  • Failure analysis

 


Your Request

Further Projects

Image

Reducing the filling quantity

How much refrigerant must be filled?

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Thermostatic Expansion Valves

Does the TXV function correctly?