Current research projects

Image Corrosion inhibitor for ammonia absorption systems
Image Modular storage system for solar cooling
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Investigation according to DIN EN ISO 14903
Image Production of novel barrier layers on polymer materials to reduce hydrogen permeation
Image Cold meter
Image Low Temperature Measuring Service
Image Innovative Parahydrogen Generator Based on Magnets
Image Calibration of Low Temperature Sensors
Image Test rigs for refrigeration and heat pump technology
Image Air-water heat pumps
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Measurement of insulated packaging
Image All-in-one device for freeze-drying and production of biomaterial
Image Performance tests of condensing units
Image Tensile and compression testing

You are here:  Home /  Measurements and Tests


Calibration of Low Temperature Sensors

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-5126

According to the comparative measurement method

Accurate and reliable measurements are the requirements for high-quality research and development or industrial production. Using the comparative measurement method the following sensors can be calibrated:

  • Resistance Temperature Detectors (RTD) with positive temperature coefficient (like Platinum or Rhodium-Iron RTDs)
  • RTD with negative temperature coefficient (like Germanium or Cernox™ RTDs)
  • Diode and thermocouples.

With an automatic measuring station several temperatures according to a sample point table will be adjusted. The calibration is carried out with secondary thermometers that are calibrated by an authority. Furthermore a fix point check with LHe or LN2 will be performed. In addition, a calbriated Cernox sensor is available for measurements in the low temperature range. The measuring facility allows the calibration of about 30 sensors at once. There are continuous extensions for different sensor types.

Parameter

IndicatorMinimalMaximal
Measuring range1.5 K350 K
Measuring accuracy5 mK (1.5 ... 4.2 K)50 mK (80 ... 350 K)
Sample dimensioncommon sensor packages
Sample preparationnot necessary

Your Request

Further Projects - Measurements and Tests

Image

Corrosion inhibitor for ammonia absorption systems

An alternative to chromium(VI) compounds

Image

Brine (water)-water heat pump

Test according DIN EN 14511 and 14825

Image

Air-water heat pumps

Test according DIN EN 14511 and 14825

Image

Electrochemical decontamination of electrically conducting surfaces „EDeKo II“

Improvement of sanitary prevention by electrochemical decontamination