Current research projects

Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Investigation of materials
Image Cold meter
Image Verification of storage suitability of cryo tubes
Image Test procedures for electrical components
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Pulse-Tube-Refrigerator with sealed compressor
Image Testing of mobile leak detectors according to DIN EN 14624
Image Influenced melting point of water by magnetic field
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Intelligent innovative power supply for superconducting coils
Image Investigation of material-dependent parameters
Image Humidifier System for High-Purity Gases
Image Non- invasive flow measurements
Image Heat2Power
Image All-in-one device for freeze-drying and production of biomaterial

You are here:  Home /  Measurements and Tests


Calibration of Low Temperature Sensors

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-5126

According to the comparative measurement method

Accurate and reliable measurements are the requirements for high-quality research and development or industrial production. Using the comparative measurement method the following sensors can be calibrated:

  • Resistance Temperature Detectors (RTD) with positive temperature coefficient (like Platinum or Rhodium-Iron RTDs)
  • RTD with negative temperature coefficient (like Germanium or Cernox™ RTDs)
  • Diode and thermocouples.

With an automatic measuring station several temperatures according to a sample point table will be adjusted. The calibration is carried out with secondary thermometers that are calibrated by an authority. Furthermore a fix point check with LHe or LN2 will be performed. In addition, a calbriated Cernox sensor is available for measurements in the low temperature range. The measuring facility allows the calibration of about 30 sensors at once. There are continuous extensions for different sensor types.

Parameter

IndicatorMinimalMaximal
Measuring range1.5 K350 K
Measuring accuracy5 mK (1.5 ... 4.2 K)50 mK (80 ... 350 K)
Sample dimensioncommon sensor packages
Sample preparationnot necessary