Current research projects

Image ZeroHeatPump
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Brine (water)-water heat pump
Image Certifiable connection types in cryogenics
Image Thermostatic Expansion Valves
Image Innovative small helium liquefier
Image Calibration leak for the water bath leak test
Image Performance tests of condensing units
Image Production of novel barrier layers on polymer materials to reduce hydrogen permeation
Image IO-Scan - Integral measuring optical scanning method
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Investigation according to DIN EN ISO 14903
Image Verification of storage suitability of cryo tubes
Image Test method for high - temperature heat pump - oils
Image Non- invasive flow measurements

You are here:  Home /  Measurements and Tests


Hydrogen and methane testing field at the ILK

BMWi

Dr. Andreas Kade

+49-351-4081-5117

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

ILK Dresden operates an innovative testing ground for cryogenic high-pressure applications with hydrogen (H2), methane (CH4), and methane–hydrogen mixtures. With this, different services can be offered, among other things:

  • Test and qualification of components at temperatures ranging from 20 K (−253 °C) to room temperature and pressures ranging from high vacuum to 1000 bar (e.g. test of sealings, permeation tests).
  • Investigation of charge and discharge processes at cryogenic or room-temperature-operated storage systems for hydrogen and methane (e.g. adsorber storage systems, cryo-compressed hydrogen).
  • Investigation of catalyst materials for the ortho–para conversion of hydrogen.
  • Long-time thermal charging of components and materials in hydrogen or methane atmosphere at up to +200 °C and up to 160 bar for investigating degradation effects (e.g. hydrogen embrittlement).
  • Development of different hydrogen and methane components (e.g. recooling systems, latent-heat storage systems, cryogenic pressure storage systems, heat exchangers, cryogenic pumps).
  • Realisation of complete-system solutions for hydrogen and methane.

The following diagram depicts the specific storage density that can be achieved depending on temperature and pressure:


Your Request

Further Projects - Measurements and Tests

Image

Low Temperature Measuring Service

Measurement of Thermal Properties at Low Temperatures

Image

Test procedures for electrical components

Insulating properties of hermetic compressors

Image

3D - Air flow sensor

Anemometer for determination of 3d-air flow