Current research projects

Image Intelligent innovative power supply for superconducting coils
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image 3D - Air flow sensor
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image CFE-Test of Cooker Hoods
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Performance tests of refrigerant compressors
Image Investigation of materials
Image Range of services laboratory analyses
Image Air-water heat pumps
Image Thermal engines
Image Low temperature – test facilities
Image ZeroHeatPump
Image Test method for high - temperature heat pump - oils
Image High Capacity Pulse Tube Cooler

You are here:  Home /  Measurements and Tests


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects - Measurements and Tests

Image

Refrigerants, lubricants and mixtures

Determination of working fluid properties

Image

Measurements on ceiling mounted cooling systems

Comparative performance measurement

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Calibration of Low Temperature Sensors

According to the comparative measurement method