Current research projects

Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Range of services laboratory analyses
Image Filter Tests
Image Corrosion inhibitor for ammonia absorption systems
Image Ionocaloric cooling
Image Humidifier System for High-Purity Gases
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Cryostats, Non-Metallic and Metallic
Image Test rigs for refrigeration and heat pump technology
Image Performance tests of refrigerant compressors
Image Influenced melting point of water by magnetic field
Image Calibration of Low Temperature Sensors
Image Reducing the filling quantity

You are here:  Home /  Measurements and Tests


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects - Measurements and Tests

Image

Corrosion inhibitor for ammonia absorption systems

An alternative to chromium(VI) compounds

Image

Brine (water)-water heat pump

Test according DIN EN 14511 and 14825

Image

Air-water heat pumps

Test according DIN EN 14511 and 14825

Image

Electrochemical decontamination of electrically conducting surfaces „EDeKo II“

Improvement of sanitary prevention by electrochemical decontamination