Current research projects

Image Low Temperature Tribology
Image Reducing the filling quantity
Image Panel with indirect evaporative cooling via membrane
Image Energy efficiency consulting - cogeneration systems
Image Preformance measurements of heat exchangers
Image Hydrogen and methane testing field at the ILK
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Investigation of materials
Image Low noise and non metallic liquid-helium cryostat
Image Software for test rigs
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Refrigerants, lubricants and mixtures
Image Testing of mobile leak detectors according to DIN EN 14624
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Service offer for Leak Detection and Tightness Test
Image Influenced melting point of water by magnetic field

You are here:  Home /  Measurements and Tests


Tribological investigations of oil-refrigerant-material-systems

Dr.-Ing. Margrit Junk

+49-351-4081-5419

Modified Almen-Wieland wear testing machine

The modified Almen-Wieland wear testing machine is used for the determination of the tribological properties of oil-refrigerant-bearing-systems under mixed friction conditions. The interaction of lubricants, additives, refrigerants and materials is tested. On the basis of these investigations refrigeration oils and materials could be preselected, but the tests can not substitute field test with refrigeration machines.

Principle

Two half bearings are pressed hydraulically against a test pin rotating horizontally in the lubricant.

The extreme pressure failure, i. e. the load bearing capacity of oil, is determined by increasing continuously or stepwise the test load until seizure of pin and bearing occurs and the pin breaks. The coefficient of friction and the wear are determined with constant (low) load applied during a prescribed test time.

Specialties

  • Hermetic test cell, which allows testing with refrigerant pressures up to 10 bar.
  • Thermostated test cell for a defined lubricant temperature.
  • Continuous record of fest force, turning moment, pressure of refrigerant, temperature and wear.
  • Use of both Almen-Wieland and half bearings with Falex geometry (dimensions of the V-block than the original Falex bearings according to ASTM D 3233).
  • Adaption of the tribological system by choosing materials of test pins and half bearings.

Our services

  • Evaluation of lubricant-refrigerant-material-systems by load bearing capacity of lubricant (extreme pressure failure load), coefficient of friction, wear, changes of lubricant
  • Evaluation of tribological systems after changing lubricants, refrigerants or bearing materials in order to minimize expensive field tests
  • Failure analysis

 


Your Request

Further Projects - Measurements and Tests

Image

Refrigerants, lubricants and mixtures

Determination of working fluid properties

Image

Measurements on ceiling mounted cooling systems

Comparative performance measurement

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Calibration of Low Temperature Sensors

According to the comparative measurement method