Current research projects

Image Innovative Parahydrogen Generator Based on Magnets
Image Practical training, diploma, master, bachelor
Image Test rigs for refrigeration and heat pump technology
Image Cryostats, Non-Metallic and Metallic
Image In-Situ-Swelling Behaviour of Polymer Materials in Flammable Fluids
Image Optimizing HVAC operation with machine learning
Image All-in-one device for freeze-drying and production of biomaterial
Image Micro heat exchangers in refrigeration
Image Energy efficiency consulting - cogeneration systems
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image High Capacity Pulse Tube Cooler
Image Corrosion inhibitor for ammonia absorption systems
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Combined building and system simulation
Image Service offer for Leak Detection and Tightness Test
Image Software for technical building equipment

You are here:   /  Home


Low temperature – test facilities

Industry and research instituts

Gunar Schroeder

+49-351-4081-5129

thermal cycling tests at very low temperatures

Parts and components of machines such as satellites or space telescopes are subject to mechanical stress. In addition to the mechanical stress, the temperatures at which these components are used also have an influence on their strength and thus also on their lifetime. In the area of materials research, material aging and especially for space applications with the very high temperature changes that occur in a vacuum, temperature change tests are essential. These tests normally are combined with subsequent strength testing. With the knowledge gained, e.g. how the component strength changes due to extreme temperature changes, the components can be optimally designed with regard to the special requirements for reliability and minimum weight.

A test chamber has been build up at the ILK Dresden specifically for such temperature change tests. With the help of this thermal cycling chamber, parts or components can be exposed to changing temperatures for different durations. The temperatures can be specified in the range of 20 – 363 K for defined time intervals. The temperature gradients, performing the change from the lowest temperature to the highest temperature or reverse can also be specified in a range. Using a programmable electronic control, temperature profiles can be defined and run through in automated test operation over several hours to several days.

Sample limits Parameter
Temperature range 20 K ... 363 K / -253°C ... +90°C / -423°F ... 194°F
Temperature stability ± 1 K
Dimension, length x width 0,95 m x 0,6 m / 3 ft x 2 ft
Mass up to 30 kg / 66 lb

 


Your Request

Further Projects

Image

Reducing the filling quantity

How much refrigerant must be filled?

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Thermostatic Expansion Valves

Does the TXV function correctly?