Current research projects

Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Computational fluid dynamics CFD
Image Low noise and non metallic liquid-helium cryostat
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Software for technical building equipment
Image Calibration leak for the water bath leak test
Image Air-water heat pumps
Image Intelligent innovative power supply for superconducting coils
Image Production of novel barrier layers on polymer materials to reduce hydrogen permeation
Image Thermal engines
Image Measurements on ceiling mounted cooling systems
Image Filter Tests
Image Non- invasive flow measurements
Image Hydrogen and methane testing field at the ILK
Image Helium extraction from natural gas
Image Performance tests of refrigerant compressors

You are here:   /  Home


Low temperature – test facilities

Industry and research instituts

Gunar Schroeder

+49-351-4081-5129

thermal cycling tests at very low temperatures

Parts and components of machines such as satellites or space telescopes are subject to mechanical stress. In addition to the mechanical stress, the temperatures at which these components are used also have an influence on their strength and thus also on their lifetime. In the area of materials research, material aging and especially for space applications with the very high temperature changes that occur in a vacuum, temperature change tests are essential. These tests normally are combined with subsequent strength testing. With the knowledge gained, e.g. how the component strength changes due to extreme temperature changes, the components can be optimally designed with regard to the special requirements for reliability and minimum weight.

A test chamber has been build up at the ILK Dresden specifically for such temperature change tests. With the help of this thermal cycling chamber, parts or components can be exposed to changing temperatures for different durations. The temperatures can be specified in the range of 20 – 363 K for defined time intervals. The temperature gradients, performing the change from the lowest temperature to the highest temperature or reverse can also be specified in a range. Using a programmable electronic control, temperature profiles can be defined and run through in automated test operation over several hours to several days.

Sample limits Parameter
Temperature range 20 K ... 363 K / -253°C ... +90°C / -423°F ... 194°F
Temperature stability ± 1 K
Dimension, length x width 0,95 m x 0,6 m / 3 ft x 2 ft
Mass up to 30 kg / 66 lb

 


Your Request

Further Projects

Image

Influenced melting point of water by magnetic field

Controlled sub-cooling of products in freezing processes

Image

Investigation of materials

Investigations regarding the compatibility of materials with refrigerants, oils and heat transfer fluids

Image
Image

Non- invasive flow measurements

PDPA - flow fields and particle sizes