Current research projects

Image Innovative Parahydrogen Generator Based on Magnets
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image All-in-one device for freeze-drying and production of biomaterial
Image Cryostats, Non-Metallic and Metallic
Image Energy efficiency consulting - cogeneration systems
Image Ionocaloric cooling
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Ice Slurry Generation
Image Thermal engines
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Measurements on ceiling mounted cooling systems
Image Hydrogen and methane testing field at the ILK
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Measurement of insulated packaging
Image Cold meter
Image Panel with indirect evaporative cooling via membrane

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³

Your Request

Further Projects

Image

Thermostatic Expansion Valves

Does the TXV function correctly?

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?

Image

Swirl-free on the move...

...with a contra-rotating fan

Image

Measurement of insulated packaging

How efficient is my cool box?