Aktuelle Forschungsprojekte

Image IN-SITU SWELLING BEHAVIOUR OF POLYMER MATERIALS IN FLAMMABLE FLUIDS
Image Swirl-free on the move...
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Solar Cooling
Image Low temperature – test facilities
Image Ice Slurry Generation
Image Innovative small helium liquefier
Image Combined building and system simulation
Image Measurements on ceiling mounted cooling systems
Image Low Temperature Measuring Service
Image Cryostats, Non-Metallic and Metallic
Image Modular storage system for solar cooling
Image All-in-one device for freeze-drying and production of biomaterial
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Lifetime prediction of hermetic compressor systems

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³