Aktuelle Forschungsprojekte

Image Characterisation of Superconductors in Hydrogen Atmosphere
Image Low Temperature Tribology
Image Air-flow test rig for fan characteristic measurement
Image Modular storage system for solar cooling
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Pulse-Tube-Refrigerator with sealed compressor
Image Performance tests of refrigerant compressors
Image Testing of mobile leak detectors according to DIN EN 14624
Image Testzentrum PLWP at ILK Dresden
Image Reduction of primary noise sources of fans
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Cool Up
Image Calibration leak for the water bath leak test
Image Corrosion inhibitor for ammonia absorption systems
Image Range of services laboratory analyses
Image Low noise and non metallic liquid-helium cryostat

You are here:   /  Home


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³