Current research projects

Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Cold meter
Image Investigation of coolants
Image Verification of storage suitability of cryo tubes
Image Heat2Power
Image Electrical components in refrigeration circuits
Image Helium extraction from natural gas
Image Reducing the filling quantity
Image Lifetime prediction of hermetic compressor systems
Image Calibration of Low Temperature Sensors
Image Thermostatic Expansion Valves
Image Pulse-Tube-Refrigerator with sealed compressor
Image CFE-Test of Cooker Hoods
Image Investigation of material-dependent parameters
Image Micro fluidic expansion valve
Image Behavior of multiphase cryogenic fluids

You are here:   /  Home


Innovative small helium liquefier

EuroNorm GmbH (BMWi)

Dr. Erik Neuber

+49-351-4081-5122

Liquefaction rates from 10 to 15 l/h

The goal of the R & D project is to explore new innovative ways to develop the functional model of a "helium liquefier for the small liquefaction rate". The development of such a system should cover the still non-existent area of the market.

 

This liquefier should contain several innovations and technical solutions:

  • Development of a helium liquefaction system with a liquefaction rate of 10 - 15 liters per hour of liquid helium.
  • Development of an innovative pre-cooling stage, which works with a mixture of helium and refrigerants as working fluid.
  • Detailed investigation of an innovative helium cycle within the development of the helium small liquefier with the ability to operate in different operating regimes: helium liquefaction, cooling and temperature stabilization/control.
  • Operation of the condenser with a liquefaction rate that can be varied over a wide range - between 75% and 100%.

Currently, the functional design of the helium small liquefier is being set up. The figure shows a 3D model of the cold box, in which all heat exchangers and cold valves are mounted. In the upper part of the cold box, two prototypes of low flow helium turboexpanders are mounted. All external components, piping and condenser control system are located on the front of the cold box.


Your Request

Further Projects

Image

Computational fluid dynamics CFD

Scientific analysis of flows

Image

Humidifier System for High-Purity Gases

Nafion - moisture transfer

Image

Behavior of multiphase cryogenic fluids

experimental und numerical investigations

Image

Innovative Parahydrogen Generator Based on Magnets

Magnetic Gas Separation of the Hydrogen Isomers