Panel with indirect evaporative cooling via membrane

INNO-KOM

01/2023 - 06/2025

Dipl.-Ing. (FH) Hannes Rosenbaum

+49-351-4081-5324

Natural Cooling Panel

Development of a decentralised cooling panel with outdoor air connection, without refrigerant, without humidity input into the room air, retrofittable and with coefficients of performance (COP) > 10

Motivation

  • GWP = 0; COP > 10; 100% renewable energy
  • Decentralised indirect evaporative cooling with no moisture in the indoor or outdoor air
  • Self-sufficient operation, rainwater harvesting
  • Radiant and convective air discharge

Project Objective

  • Application of regenerative and sustainable cooling via evaporative cooling in a decentralised air conditioning system (COP > 10)
  • Functional combination of evaporative cooling and supply of purified outdoor air
  • Novel membrane heat exchanger for two air streams and evaporation water including numerical calculation model
  • Novel convection and radiation efficient air outlet for minimum draught risk
  • Modular, cascadable unit concept for on-demand performance and off-grid and CO2-neutral operation (for PV power supply)
  • Ceiling-mounted, wall-mounted or free-standing cooling panels for residential and non-residential buildings, retrofittable and acoustically compliant

Solution Approach

  • Development of a membrane heat exchanger based on 4-layer textile laminates
  • Development of equipment based on supply air recirculation and exhaust air humidification processes
  • Development of an air outlet for convection and radiation cooling performance
  • MSR and system components for rainwater harvesting, site-independence and cascading

Your Request

Further Projects

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Thermostatic Expansion Valves

Does the TXV function correctly?

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?

Image

Swirl-free on the move...

...with a contra-rotating fan