Current research projects

Image Calibration leak for the water bath leak test
Image High Capacity Pulse Tube Cooler
Image Practical training, diploma, master, bachelor
Image Software for technical building equipment
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Pulse-Tube-Refrigerator with sealed compressor
Image Testzentrum PLWP at ILK Dresden
Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Computational fluid dynamics CFD
Image Investigation of material-dependent parameters
Image Performance tests of condensing units
Image Reduction of primary noise sources of fans
Image Laseroptical measurement
Image Heat2Power
Image Intelligent innovative power supply for superconducting coils

You are here:   /  Home


Preformance measurements of heat exchangers

Industry

Dipl.-Ing. Markus Müller

+49-351-4081-5218

Is the heat exchanger properly sized?

We support the industry to improve the efficiency of components for cooling systems and heat pumps.

The ILK Dresden offers the following services:

We determine the preformance and pressure losses of plate heat exchangers (evaporators and condensors) or other heat exchangers for liquids in a defined range.
The measurment is based on the following norms

  • DIN EN 306 Heat exchangers - Methods of measuring the parameters necessary for establishing the performance
  • DIN EN 1117 Heat exchangers - Liquid cooled refrigerant condensors - Test procedures for establishing the performance
  • DIN EN 1118 Heat exchangers - Refrigerant cooled liquid coolers - Test procedure for establishing the performance

The test are preformed at a special developed test rig, which can be seen on the following picture.

Operation range of the test rig

  • Kältemittel: Refrigerants: R134a, R404a, R407C, R410A, R507, (others on request)
  • Coolant: Brine
  • Heat carrier: Water
  • Maximum Performance condensor: 70 kW
  • Maximum Performance evaporator: 60 kW

The measurement systems are calibrated regularly.

Additional services

We can support you at following tasks

  • Technical design of components
  • Optimisation of components
  • Software development for technical design and optimisation

Also we can offer you

  • static and time-varying thermal simulations
  • thermography of components

The ILK Dresden has many expertise and a high flexibility in the field of air and refrigeration technology. You will benefit from the broad spectrum of our research directions and technologies as well as the integration of various fields of expertise.


Your Request

Further Projects

Image

Software for technical building equipment

Design cooling load and energetic annual simulation (VDI 2078, VDI 6007, VDI 6020)

Image

Measurements on ceiling mounted cooling systems

Comparative performance measurement

Image

Micro fluidic expansion valve

for increasing of the efficiency of small and compact cooling units

Image

Solar Cooling

Solar Cooling with Photovoltaic

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C