Current research projects

Image Low Temperature Tribology
Image Mass Spectrometer
Image All-in-one device for freeze-drying and production of biomaterial
Image Verification of storage suitability of cryo tubes
Image Certifiable connection types in cryogenics
Image Laseroptical measurement
Image Filter Tests
Image Intelligent innovative power supply for superconducting coils
Image Service offer for Leak Detection and Tightness Test
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Investigation of coolants
Image Performance tests of refrigerant compressors
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Heat2Power
Image Measurements on ceiling mounted cooling systems

You are here:   /  Home


Tensile and compression testing

Industry and research institutes

Gunar Schroeder

+49-351-4081-5129

Determination of yield strength, tensile strength and elongation at break

A tensile or compression test is a quasi-static, destructive test method for determining material characteristics such as yield strength, tensile strength and elongation at break. The specimen form and the procedure of such tests are standardized. The ISO 9862 standard defines the exact procedure and the measured variables to be recorded for metallic materials and the DIN 50125 standard defines the specimen shape and its production method. In addition, the arrangement can generally be used to record force-displacement curves with high accuracy.

To carry out the test, the specimens are clamped centrally in the grippers or positioned centrally between the compression plates. In the tensile test, the specimens are pulled apart in a defined manner. In the compression test, on the other hand, a compressive force is applied to the test specimen, e.g. rectangular prisms, cylinders or tubes, in a uniaxial stress state. In both tests, the force and change in length are recorded continuously and evaluated graphically. On request, the tensile and compression test can be carried out at very low temperatures.

Parameter Limit values samples
Materials foils, plastics, composites, metals
Typical dimension of plastic samples Lר: 200×10 mm (7.8"×0.4") or
L×W×H: 200×10×10 mm (7.8"×0.4"×0.4")
Measurement range of force and displacement ±5 kN (±1124 lbf), 400 mm (15.8")
Standardized testing force-distance, force-time, tension-extension

 


Your Request

Further Projects

Image

Measurement of insulated packaging

How efficient is my cool box?

Image

Hybrid- Fluid for CO2-Sublimation Cycle

Cryogenic cooling by CO2 sublimation

Image

Energy efficiency consulting - cogeneration systems

How efficient is my refrigeration system?

Image

Cold meter

The fast way to refrigerating capacity

Image

Optimizing HVAC operation with machine learning

Intelligent control of HVAC systems – high comfort with low energy demand