Current research projects

Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Multifunctional electronic modules for cryogenic applications
Image Low noise and non metallic liquid-helium cryostat
Image Air-water heat pumps
Image Influenced melting point of water by magnetic field
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Software for test rigs
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Thermostatic Expansion Valves
Image Test method for high - temperature heat pump - oils
Image Heat2Power
Image Reduction of primary noise sources of fans
Image 3D - Air flow sensor
Image Performance tests of condensing units
Image Cold meter
Image Lifetime prediction of hermetic compressor systems

You are here:  Home /  Measurements and Tests


Calibration of Low Temperature Sensors

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-5126

According to the comparative measurement method

Accurate and reliable measurements are the requirements for high-quality research and development or industrial production. Using the comparative measurement method the following sensors can be calibrated:

  • Resistance Temperature Detectors (RTD) with positive temperature coefficient (like Platinum or Rhodium-Iron RTDs)
  • RTD with negative temperature coefficient (like Germanium or Cernox™ RTDs)
  • Diode and thermocouples.

With an automatic measuring station several temperatures according to a sample point table will be adjusted. The calibration is carried out with secondary thermometers that are calibrated by an authority. Furthermore a fix point check with LHe or LN2 will be performed. In addition, a calbriated Cernox sensor is available for measurements in the low temperature range. The measuring facility allows the calibration of about 30 sensors at once. There are continuous extensions for different sensor types.

Parameter

IndicatorMinimalMaximal
Measuring range1.5 K350 K
Measuring accuracy5 mK (1.5 ... 4.2 K)50 mK (80 ... 350 K)
Sample dimensioncommon sensor packages
Sample preparationnot necessary

Your Request

Further Projects - Measurements and Tests

Image

Mass Spectrometer

Determining the composition of gas mixtures in the high or ultra-high vacuum range

Image

Tensile and compression testing

Determination of yield strength, tensile strength and elongation at break

Image

Investigation of material-dependent parameters

Investigation of the permeation behavior

Image

Breakthrough Sensor for Adsorption Filters (BelA)

Sensor system for detecting an imminent breakthrough in gas filtration