Aktuelle Forschungsprojekte

Image Behavior of multiphase cryogenic fluids
Image Reduction of primary noise sources of fans
Image Cool Up
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Brine (water)-water heat pump
Image Energy efficiency consulting - cogeneration systems
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image 3D - Air flow sensor
Image Hydrogen and methane testing field at the ILK
Image Range of services laboratory analyses
Image Intelligent innovative power supply for superconducting coils
Image Multifunctional electronic modules for cryogenic applications
Image Preformance measurements of heat exchangers
Image Test procedures for electrical components
Image Software modules

You are here:  Home /  Measurements and Tests


Hydrogen and methane testing field at the ILK

BMWi

Dr. Andreas Kade

+49-351-4081-5117

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

ILK Dresden operates an innovative testing ground for cryogenic high-pressure applications with hydrogen (H2), methane (CH4), and methane–hydrogen mixtures. With this, different services can be offered, among other things:

  • Test and qualification of components at temperatures ranging from 20 K (−253 °C) to room temperature and pressures ranging from high vacuum to 1000 bar (e.g. test of sealings, permeation tests).
  • Investigation of charge and discharge processes at cryogenic or room-temperature-operated storage systems for hydrogen and methane (e.g. adsorber storage systems, cryo-compressed hydrogen).
  • Investigation of catalyst materials for the ortho–para conversion of hydrogen.
  • Long-time thermal charging of components and materials in hydrogen or methane atmosphere at up to +200 °C and up to 160 bar for investigating degradation effects (e.g. hydrogen embrittlement).
  • Development of different hydrogen and methane components (e.g. recooling systems, latent-heat storage systems, cryogenic pressure storage systems, heat exchangers, cryogenic pumps).
  • Realisation of complete-system solutions for hydrogen and methane.

The following diagram depicts the specific storage density that can be achieved depending on temperature and pressure:


Your Request

Further Projects - Measurements and Tests

Image

Non- invasive flow measurements

PDPA - flow fields and particle sizes

Image

Laseroptical measurement

PIV and LDA / PDA

Image

Performance tests of condensing units

Does your condensing unit perform well?