Current research projects

Image State of system and failure analyses
Image Computational fluid dynamics CFD
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Lifetime prediction of hermetic compressor systems
Image Tensile and compression testing
Image Software for technical building equipment
Image Pulse-Tube-Refrigerator with sealed compressor
Image Investigation of material-dependent parameters
Image Cryostats, Non-Metallic and Metallic
Image High temperature heat pump
Image Investigation according to DIN EN ISO 14903
Image Low noise and non metallic liquid-helium cryostat
Image 3D - Air flow sensor
Image Behavior of multiphase cryogenic fluids
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Thermostatic Expansion Valves

You are here:  Home /  Research and Development


IO-Scan - Integral measuring optical scanning method

INNO-KOM

02/2022 - 07/2024

M.Sc. Rebekka Grüttner

+49-351-4081-5314

IO-Scan

Development of a photometric measurement method for determining the air exchange rate in indoor areas

Motivation

  • Cost-effective, real-time assessment of indoor air quality in the form of air exchange rates
  • Verify and optimise the effectiveness of ventilation systems in occupied areas
  • Ability to evaluate aerosol reduction through the interaction of window ventilation, building ventilation system and mobile room air cleaners

Project Objective

  • Self-calibrating measuring system
  • Deviation from previous trace gas measurements should be within 10%.
  • Real-time results can detect and evaluate the influence of changes in the ventilation system during the measurement process
  • Intended measurement depth in the room: 1 m to 50 m

Solution Approach

  • The introduction of mist aerosols into the room air influences the light transmittance to be measured.
  • Transmittance of an air-aerosol mixture and use of measured transmittance to determine air exchange rate
  • Integral real-time optical measurement over individual indoor distances

[Translate to EN:] Ergebnisse / Aktueller Stand

[Translate to EN:]

[Translate to EN:]

[Translate to EN:]


Your Request

Further Projects - Research and Development

Image

Hydrogen and methane testing field at the ILK

Simultaneously pressures up to 1,000 bar, temperatures down to –253°C

Image

Low noise and non metallic liquid-helium cryostat

Low-noise Magnetic Field Cryostat for SQUID-Applications

Image

Cryostats, Non-Metallic and Metallic

position indenpendent, highest endurance, tiltable for liquid helium and liquid nitrogen

Image

Calibration of Low Temperature Sensors

According to the comparative measurement method