Current research projects

Image Air-water heat pumps
Image In-situ investigation concerning the swelling behaviour of polymer materials under elevated pressures and temperatures
Image Humidifier System for High-Purity Gases
Image Tribological investigations of oil-refrigerant-material-systems
Image Intelligent innovative power supply for superconducting coils
Image Investigation of materials
Image Computational fluid dynamics CFD
Image Low Temperature Tribology
Image Investigation according to DIN EN ISO 14903
Image Cold meter
Image CFE-Test of Cooker Hoods
Image Test procedures for electrical components
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Lifetime prediction of hermetic compressor systems
Image Test rigs for refrigeration and heat pump technology
Image Swirl-free on the move...

You are here:   /  Home


Calibration of Low Temperature Sensors

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-5126

According to the comparative measurement method

Accurate and reliable measurements are the requirements for high-quality research and development or industrial production. Using the comparative measurement method the following sensors can be calibrated:

  • Resistance Temperature Detectors (RTD) with positive temperature coefficient (like Platinum or Rhodium-Iron RTDs)
  • RTD with negative temperature coefficient (like Germanium or Cernox™ RTDs)
  • Diode and thermocouples.

With an automatic measuring station several temperatures according to a sample point table will be adjusted. The calibration is carried out with secondary thermometers that are calibrated by an authority. Furthermore a fix point check with LHe or LN2 will be performed. In addition, a calbriated Cernox sensor is available for measurements in the low temperature range. The measuring facility allows the calibration of about 30 sensors at once. There are continuous extensions for different sensor types.

Parameter

IndicatorMinimalMaximal
Measuring range1.5 K350 K
Measuring accuracy5 mK (1.5 ... 4.2 K)50 mK (80 ... 350 K)
Sample dimensioncommon sensor packages
Sample preparationnot necessary

Your Request

Further Projects

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Thermostatic Expansion Valves

Does the TXV function correctly?

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?