Current research projects

Image Lifetime prediction of hermetic compressor systems
Image Modular storage system for solar cooling
Image Hybrid- Fluid for CO2-Sublimation Cycle
Image Performance tests of refrigerant compressors
Image Mass Spectrometer
Image Innovative Parahydrogen Generator Based on Magnets
Image Tribological investigations of oil-refrigerant-material-systems
Image Test procedures for electrical components
Image High Capacity Pulse Tube Cooler
Image Hydrogen and methane testing field at the ILK
Image Filter Tests
Image Characterisation of Superconductors in Hydrogen Atmosphere
Image All-in-one device for freeze-drying and production of biomaterial
Image Reduction of primary noise sources of fans
Image Verification of storage suitability of cryo tubes
Image Refrigerants, lubricants and mixtures

You are here:   /  Home


Certifiable connection types in cryogenics

BMWI

Dr. Andreas Kade

+49-351-4081-5117

Detachable and permanent connections, adhesive bond / form closure / force closure

The applications of cryogenic and vacuum technology impose special requirements on connection technologies. To determine the appropriate connections the application parameters such as temperature, vacuum and pressure, leak rate, materials, surface properties, radiation resistance, magnetic permeability etc. should be considered.

Connection technologies even if not being part of a standardized process more often have to be subject of a certification or qualification due to increasing quality requirements, e.g. pressure equipment directive 2014/68/EU. Therefore adequate designing and testing is necessary.

Innovations

The intended innovations relate to complete cryogenic systems considering the process chain from room temperature to low temperature range regarding the respectively required specifications. 

  • Development of application-related connection technologies with defined requirements and derived mechanical limit values 
  • Examination of existing connection technologies regarding applicability and further development towards secure and functional technologies
  • Evaluation and definition of application limits to aim for a feasible certification and the subsequent conformity with European guidelines

Project objectives

  • Application-related examination of various connection technologies
  • Further development and adaptation of existing connections to the requirements of cryogenic and vacuum technology
  • Examination on composite materials 
  • Examination on component geometries and their influence on the connection
  • Determination of process parameters (e.g. TIG welding, brazing,...) 
  • Determination of test limit values, especially for test specimens deviating from standards
  • Calculation according to common standards, simulation (FEM, ...) and testing
  • Realization and certification of selected connection technologies

Your Request

Further Projects

Image

Reducing the filling quantity

How much refrigerant must be filled?

Image

Performance tests of condensing units

Does your condensing unit perform well?

Image

State of system and failure analyses

Cause of the failure unknown?

Image

Thermostatic Expansion Valves

Does the TXV function correctly?