Current research projects

Image Electrochemical decontamination of electrically conducting surfaces „EDeKo II“
Image Optimizing HVAC operation with machine learning
Image Reduction of primary noise sources of fans
Image Innovative Parahydrogen Generator Based on Magnets
Image Combined building and system simulation
Image Certification of efficient air conditioning and ventilation systems through the new "indoor air quality seal" for non-residential buildings
Image Hydrogen and methane testing field at the ILK
Image Low noise and non metallic liquid-helium cryostat
Image Testzentrum PLWP at ILK Dresden
Image High Capacity Pulse Tube Cooler
Image Computational fluid dynamics CFD
Image Reducing the filling quantity
Image CFE-Test of Cooker Hoods
Image Cool Up
Image Cold meter
Image Ice Slurry Generation

You are here:   /  Home


IO-Scan - Integral measuring optical scanning method

INNO-KOM

02/2022 - 07/2024

M.Sc. Rebekka Grüttner

+49-351-4081-5314

IO-Scan

Development of a photometric measurement method for determining the air exchange rate in indoor areas

Motivation

  • Cost-effective, real-time assessment of indoor air quality in the form of air exchange rates
  • Verify and optimise the effectiveness of ventilation systems in occupied areas
  • Ability to evaluate aerosol reduction through the interaction of window ventilation, building ventilation system and mobile room air cleaners

Project Objective

  • Self-calibrating measuring system
  • Deviation from previous trace gas measurements should be within 10%.
  • Real-time results can detect and evaluate the influence of changes in the ventilation system during the measurement process
  • Intended measurement depth in the room: 1 m to 50 m

Solution Approach

  • The introduction of mist aerosols into the room air influences the light transmittance to be measured.
  • Transmittance of an air-aerosol mixture and use of measured transmittance to determine air exchange rate
  • Integral real-time optical measurement over individual indoor distances

[Translate to EN:] Ergebnisse / Aktueller Stand

[Translate to EN:]

[Translate to EN:]

[Translate to EN:]


Your Request

Further Projects

Image

Thermostatic Expansion Valves

Does the TXV function correctly?

Image

Testzentrum PLWP at ILK Dresden

Test Fluid-Energy Machines and Components

Image

Performance tests of refrigerant compressors

Does your compressor perform well?

Image

Swirl-free on the move...

...with a contra-rotating fan

Image

Measurement of insulated packaging

How efficient is my cool box?