Current research projects

Image Heat2Power
Image Influenced melting point of water by magnetic field
Image State of system and failure analyses
Image Solar Cooling
Image Air-flow test rig for fan characteristic measurement
Image Low Temperature Measuring Service
Image Air-water heat pumps
Image Combined building and system simulation
Image Test rigs for refrigeration and heat pump technology
Image Multifunctional electronic modules for cryogenic applications
Image All-in-one device for freeze-drying and production of biomaterial
Image Overall System Optimization of Refrigeration Plant Systems for Energy Transition and Climate Protection
Image Thermostatic Expansion Valves
Image Brine (water)-water heat pump
Image Innovative Parahydrogen Generator Based on Magnets
Image Investigation of material-dependent parameters

You are here:   /  Home


Thermostatic Expansion Valves

Industry

Dr.-Ing. Matthias Böhm

+49-351-4081-5211

Does the TXV function correctly?

We support the industry in the development of energy-efficient vapor-compression refrigeration system and compression heat pumps.

The ILK Dresden offers the following services for you:

The ILK Dresden have been active in the field of performance testing of refrigeration compressors and condensing units for over 20 years.

Our offer includes also the investigation of thermostatic expansion valves (TEV) with external temperature sensors.

The tests of the TEV are carried out on a suitable refrigeration cycles (fig. 2), taking into account the following standards

  • AHRI 750 (2007),
  • ANSI/ ASHRAE 17 (2008, fig. 1) and
  • ASERCOM-Statement (9_GER_Dimensionierung_von_TXV_2011)

Current calibrations of the measuring systems are a matter of course.

The test can be carried out with the refrigerants R134a, R404A, R407A, R407C, R407F, R448A, R513A, R452A up to a mass flow of 400 kg/h (~20 kW for R134a).

Additional offerings

The following influences on the valve behaviour can be investigated

  • run-in period
  • hysteresis
  • transient tests / time constant
  • pressure losses
  • sub cooling
  • ambient temperature
  • critical pressure ratio

Your Request

Further Projects

Image

Swirl-free on the move...

...with a contra-rotating fan

Image

Measurement of insulated packaging

How efficient is my cool box?

Image

Hybrid- Fluid for CO2-Sublimation Cycle

Cryogenic cooling by CO2 sublimation

Image

Energy efficiency consulting - cogeneration systems

How efficient is my refrigeration system?

Image

Cold meter

The fast way to refrigerating capacity