Aktuelle Forschungsprojekte

Image Low noise and non metallic liquid-helium cryostat
Image Intelligent innovative power supply for superconducting coils
Image Verification of storage suitability of cryo tubes
Image Preformance measurements of heat exchangers
Image High Capacity Pulse Tube Cooler
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Filter Tests
Image Cryostats, Non-Metallic and Metallic
Image State of system and failure analyses
Image Air-water heat pumps
Image Lifetime prediction of hermetic compressor systems
Image Investigation of materials
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Computational fluid dynamics CFD
Image Development of a Cryogenic Magnetic Air Separation Unit
Image Testing of mobile leak detectors according to DIN EN 14624

You are here:  Home /  Research and Development


Calibration of Low Temperature Sensors

Industry and R&D

Dr. rer. nat. Matthias Schneider

+49-351-4081-5126

According to the comparative measurement method

Accurate and reliable measurements are the requirements for high-quality research and development or industrial production. Using the comparative measurement method the following sensors can be calibrated:

  • Resistance Temperature Detectors (RTD) with positive temperature coefficient (like Platinum or Rhodium-Iron RTDs)
  • RTD with negative temperature coefficient (like Germanium or Cernox™ RTDs)
  • Diode and thermocouples.

With an automatic measuring station several temperatures according to a sample point table will be adjusted. The calibration is carried out with secondary thermometers that are calibrated by an authority. Furthermore a fix point check with LHe or LN2 will be performed. In addition, a calbriated Cernox sensor is available for measurements in the low temperature range. The measuring facility allows the calibration of about 30 sensors at once.

Parameter

IndicatorMinimalMaximal
Measuring range1.5 K350 K
Measuring accuracy5 mK (1.5 ... 4.2 K)50 mK (80 ... 350 K)
Sample dimensioncommon sensor packages
Sample preparationnot necessary

Your Request

Further Projects - Research and Development

Image

Corrosion inhibitor for ammonia absorption systems

An alternative to chromium(VI) compounds

Image

Development of a Cryogenic Magnetic Air Separation Unit

Oxygen Enrichment by Applied Cryogenic Magnetohydrodynamics

Image

Brine (water)-water heat pump

Test according DIN EN 14511 and 14825

Image

Air-water heat pumps

Test according DIN EN 14511 and 14825

Image

High temperature heat pump

Using waste heat from industrial processes


Contact

Institut für Luft- und Kältetechnik - Gemeinnützige Gesellschaft mbH
Bertolt-Brecht-Allee 20, 01309 Dresden


Reception ILK Dresden

+49-351-4081-5000

+49-351-4081-5099

Image ISO 9001
Bild Zuse Mitglied Bild SIG