Current research projects

Image Corrosion inhibitor for ammonia absorption systems
Image CFE-Test of Cooker Hoods
Image Ionocaloric cooling
Image Innovative cryogenic cooling system for the recondensation / liquefaction of technical gases up to 77 K
Image Cold meter
Image Measurement of insulated packaging
Image Thermostatic Expansion Valves
Image Air-water heat pumps
Image Low Temperature Tribology
Image Innovative Parahydrogen Generator Based on Magnets
Image Industry 4.0 membrane heat and mass exchanger (i-MWÜ4.0)
Image Reducing the filling quantity
Image Optimizing HVAC operation with machine learning
Image Range of services laboratory analyses
Image Cryostats, Non-Metallic and Metallic
Image Behavior of multiphase cryogenic fluids

You are here:  Home /  Research and Development


Low temperature – test facilities

Industry and research instituts

Gunar Schroeder

+49-351-4081-5129

thermal cycling tests at very low temperatures

Parts and components of machines such as satellites or space telescopes are subject to mechanical stress. In addition to the mechanical stress, the temperatures at which these components are used also have an influence on their strength and thus also on their lifetime. In the area of materials research, material aging and especially for space applications with the very high temperature changes that occur in a vacuum, temperature change tests are essential. These tests normally are combined with subsequent strength testing. With the knowledge gained, e.g. how the component strength changes due to extreme temperature changes, the components can be optimally designed with regard to the special requirements for reliability and minimum weight.

A test chamber has been build up at the ILK Dresden specifically for such temperature change tests. With the help of this thermal cycling chamber, parts or components can be exposed to changing temperatures for different durations. The temperatures can be specified in the range of 20 – 363 K for defined time intervals. The temperature gradients, performing the change from the lowest temperature to the highest temperature or reverse can also be specified in a range. Using a programmable electronic control, temperature profiles can be defined and run through in automated test operation over several hours to several days.

Sample limits Parameter
Temperature range 20 K ... 363 K / -253°C ... +90°C / -423°F ... 194°F
Temperature stability ± 1 K
Dimension, length x width 0,95 m x 0,6 m / 3 ft x 2 ft
Mass up to 30 kg / 66 lb

 


Your Request

Further Projects - Research and Development

Image

ZeroHeatPump

Performance management of small heat pumps without energy consumption

Image

Investigation of material-dependent parameters

Investigation of the permeation behavior

Image

Cool Up

Upscaling Sustainable Cooling

Image

Ionocaloric cooling

Ionocaloric solid-liquid phase cooling process