Current research projects

Image Range of services laboratory analyses
Image Certifiable connection types in cryogenics
Image Thermostatic Expansion Valves
Image Breakthrough Sensor for Adsorption Filters (BelA)
Image Swirl-free on the move...
Image Investigation of coolants
Image Innovative Manufacturing Technologies for Cryosorption Systems
Image Multifunctional electronic modules for cryogenic applications
Image Production of novel barrier layers on polymer materials to reduce hydrogen permeation
Image All-in-one device for freeze-drying and production of biomaterial
Image Development of test methods and test rigs for stationary integrated refrigeration units
Image Brine (water)-water heat pump
Image Lifetime prediction of hermetic compressor systems
Image State of system and failure analyses
Image Optimizing HVAC operation with machine learning
Image Software modules

You are here:  Home /  Testing Equipment


Humidifier System for High-Purity Gases

Industry and Research Instituts

Moritz Kuhn

+49-351-4081-5120

Nafion - moisture transfer

At the ILK Dresden a humidification system was developed and manufactured which is especially suitable for research facilities where very low dew point temperatures have to be adjusted and at the same time a high gas purity has to be guaranteed. The core component is a PermaPure® humidifier with Nafion® moisture exchange. The humidification system precisely controls the dew point via a bypass mixing with dry gas and also takes over the automatic filling of evacuated containers. The control system is optimised to prevent recondensation. Humidification can be controlled from any plant system via an interface. Table 1 shows the technical data of a humidification system for the humidification of synthetic air realized for the KIT in Karlsruhe. The system can be adapted for other applications, and all parameters can be adjusted to the respective requirements.

Table  1: Technical Data Humidifier System
Parameter Value
setpoint gas flow 750 litre/min
maximum relative humidity 95%
minimum dew point -60°C / -76°F
degree of gas purity 5.0
gas purity, number of particle < 5 particle/cm³